Cambio - Excellence in Molecular Biology

qPCR and qRT-PCR

qPCR and qRT-PCR: qPCR Master Mixes

qPCR based reference gene panels for Humans, mouse and rat ( SYBR and FAM based)

TATAA Multiplex GrandMaster Mixes

TATAA Interplate Calibrator

The TATAA Interplate Calibrator (IPC) makes it possible for you to compensate for variations between qPCR runs. For practical reasons many qPCR studies involve the use of samples that are processed in more than a single batch or in which the sample set is extended over time. Even over a short time period, variation between qPCR processing runs is observed due to different baseline subtractions and threshold settings.

Tataa Biocenter

Catalogue No.DescriptionPack SizePriceQty
IPC1000PFAMTATAA Interplate Calibrator Probe FAM1000 rxns POA Quantity Add to Order
IPC1000PHEXTATAA Interplate Calibrator Probe HEX1000 rxns POA Quantity Add to Order
IPC1000STATAA Interplate Calibrator SYBR®1000 rxns POA Quantity Add to Order
IPC250PFAMTATAA Interplate Calibrator Probe FAM250 rxns POA Quantity Add to Order
IPC250PHEXTATAA Interplate Calibrator Probe HEX250 rxns £371.00 Quantity Add to Order
IPC250STATAA Interplate Calibrator SYBR®250 rxns £329.00 Quantity Add to Order

Description

Variation Compensation


The TATAA Interplate Calibrator (IPC) makes it possible for you to compensate for variations between qPCR runs. For practical reasons many qPCR studies involve the use of samples that are processed in more than a single batch or in which the sample set is extended over time. Even over a short time period, variation between qPCR processing runs is observed due to different baseline subtractions and threshold settings.

When to use TATAA Interplate Calibrator


The bias is NOT introduced when using the “all samples” or “all assays” plate layout or when performing ΔΔCq based analysis, but it is the “mixed” layout for which interplate calibration is needed (Figure 1). The TATAA IPC sample material is provided in ready-to-use aliquots and is a very stable template that is amplified with a highly robust assay. The TATAA IPC should be included in all qPCR runs. Any differences in the measured IPC Cq-values among the runs reflect the bias introduced by the instrument and can then compensated for.

TATAA Interplate Calibrator is:

  • provided in aliquots (stored at -20°C) for easy and flexible use and long term stability
  • a robust assay that performs excellent in most mastermixes and over a wide range of annealing temperatures
  • a stable template at optimum concentration that produces Cq ≈ 15 -20 under most conditions

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200