Cambio - Excellence in Molecular Biology

Transfection-EZ Biosystems

Transfection-EZ Biosystems: Cell Lines

Avalanche®- Cell Line-specific Transfection Reagent series:

Perform maximum transfection efficiency for more than 170 different primary cells and cell lines including 124 cancer cell lines (e.g. All of NCI60 cancer cell lines). Each of the cell type/cell line-specific transfection reagents in our Avalanche® series was individually formulated.

If you are looking for primary cell type-transfection reagents then click Click here

 


 

Learn why you should use Avalanche® Cell Type-Specific Transfection reagents

 

How EZ Biosystems developed Avalanche® Cell Type-Specific Transection Reagents

 



MCF7 Cell Avalanche® Transfection Reagent (human breast carcinoma cell)

MCF7 Cell Avalanche® Transfection Reagent is a new, proprietary solution specifically designed for transfection on MCF7 cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for MCF7 cells. No other transfection reagents can match the efficiency, convenience, and gentleness of MCF7 Cell Avalanche® Transfection Reagent for transfection on MCF7 cells

EZ Biosystems

Catalogue No.DescriptionPack SizePriceQty
EZT-MCF7-1-05MCF7 Cell Transfection Reagent (human breast carcinoma cell)0.5 ml £620.00 Quantity Add to Order
EZT-MCF7-1-15MCF7 Cell Transfection Reagent (human breast carcinoma cell)1.5ml £1,051.00 Quantity Add to Order

Description

Cell Line Information:
Cell Line Name: MCF7 (ATCC® HTB-22™)  
Organism: Homo sapiens, human
Tissue: mammary gland; breast: pleural effusion
Cell Type: epithelial
Morphology: epithelial
Culture Properties: adherent
Disease: adenocarcinoma
Age: 69 years adult
Gender    : female
Ethnicity: Caucasian
Applications: These cells are suitable as a transfection host.
estrogen receptor, expressed
Genes Expressed: insulin-like growth factor binding proteins (IGFBP) BP-2; BP-4; BP-5,Blood Type O; Rh

Comments: The MCF7 line retains several characteristics of differentiated mammary epithelium including ability to process estradiol via cytoplasmic estrogen receptors and the capability of forming domes. The cells express the WNT7B oncogene.
MCF7 is one of the cell lines of the NCI-60 panel which represents different cancer types and has been widely utilized for drug screening and molecular target identification.

The Transfection Reagent:
MCF7 Cell Avalanche® Transfection Reagent is a new, proprietary solution specifically designed for transfection on MCF7 cells. The proprietary formulation of lipids and polymers ensures the highest possible transfection efficiencies and viabilities for MCF7 cells. No other transfection reagents can match the efficiency, convenience, and gentleness of MCF7 Cell Avalanche® Transfection Reagent for transfection on MCF7 cells. For details of the developing process of this reagent, please go to: How did EZ Biosystems develop Avalanche® Cell type/cell line specific transfection reagent series?
 

Features:

  • Specifically optimized to deliver nucleic acids into MCF7 cells
  • Highest efficiency to ensure experimental success
  • Extremely gentle to cells
  • Deliver single or multiple plasmids
  • Synthesized from 100% animal origin-free components, making it easy to validate the absence of zoonotic diseases, such as BSE or viruses, in research experiments or cells lines
  • Simplest and straightforward protocols to Increase experimental throughput
  • Compatible with serum
  • Suitable for Reverse Transfection  
  • Compatible with transfection in any plate format
  • Great pricing
  • Developed and manufactured by EZ Biosystems
     
 
Data:
FIG. 1. High throughput test of transfection efficiency (determined as RLU/mg) on MCF7 cells after transfection of luciferase reporter gene by using our 172 proprietary transfection formulas and several most popular commercial transfection reagents. The yellow box showed the results of 4 commercial transfection reagents. The red lines marked our candidate formulas with the highest transfection efficiency for MCF7 cells. This test result was confirmed with repeat experiments. The one that showed the optimal balance of potent & low cytotoxicity among those candidate formulas after flow cytometry analysis on the percentage of 7AAD positive cells was later named as this MCF7 Cell Avalanche® Transfection Reagent.
 
FIG. 2. MCF7 cells were transfected with GFP vector (pEGFP-N3) by using MCF7 Cell Avalanche® Transfection Reagent. The cells were visualized by Nikon Eclipse Fluorescence microscope 48 hours post transfection.
 

For Other Cells:
MCF7 Cell Avalanche® Transfection Reagent (human breast carcinoma cell) can also be used on the following cells with high transfection efficiencies.

BT-20 Cell
HCC1937 Cell
Hs-578-T Cell
T47D cell
MDA-MB-468 Cell
SK-BR-3 Cell
MDA-MB-231 Cell
293 Cell
293T/17 Cell

Recommended protocols for these cells will be provided with the reagent. The protocols usually provide satisfactory transfection efficiency with invisible cytotoxicity. However, optimization may be needed for certain type of cells. Optimizations may include: the amount of DNA and this transfection reagent; cell density; transfection reagent/DNA ratio, or incubation time for the mixture of transfection reagent/DNA etc. For best transfection result, we recommend using the respective cell type/cell line specific Avalanche transfection reagents. Those reagents have been optimized on both recipes and protocols, and have been proved to have the best transfection results for the respective cell lines or primary cells. You can easily find the respective Avalanche transfection reagents specific for your cells by using the filters of our product list.

If you cannot find the answer to your problem then please contact us or telephone +44 (0)1954 210 200